• Catalogue Shom
  •  
  •  
  •  

  Time series of turbidity

In early 2017, Shom established a near-bottom turbidity observation network to measure turbidity and currents near the seabed continuously, at high frequency and over a long period of time (several years). Seven mooring points with ecological and / or sedimentological interests and impacted by anthropogenic activities (except the control point in the Celtic Sea) have thus been defined. The product "Turbidity Time Series ROEC" contains turbidity level records measured in NTU by optical turbidimeters implanted at each of the 7 wetting points of the monitoring network. The data present in the product "ROEC Turbidity Time Series" corresponds to raw data from NTUS sensors (Wetlabs) deployed on different moorings and transcoded in .CSV format. The time series are provided in their entirety and have not been post-processed. The files can therefore include certain erroneous values ​​related to specific anomalies in the acquisition made by the sensor or intervals without data when the acquisition knows ranges of interruption.

 
Citation proposal
(2019) . Time series of turbidity. https://services.data.shom.fr:/geonetwork/srv/api/records/ROEC_TURBI
 

Simple

Date ( Publication )
2019-05-24
Identifier

http://www.shom.fr/HOM/ROEC_TURBI

  Point of contact

Shom Shom  

13 rue du Chatellier - CS 92803

BREST

29228

France


Keywords ( Theme )
  • sediment

  • turbidity

  • open data

GEMET - INSPIRE themes, version 1.0 GEMET - INSPIRE themes, version 1.0 ( Theme )
  • Oceanographic geographical features

Use limitation

Data may be freely used providing that the source is mentioned. https://doi.org/10.17183/roec_turbi

Use limitation

Do not use for navigation

Use limitation

The product is distributed under an Opendata license (version 2.0, April 2017), defined by the Etalab mission.

Access constraints
License
Use constraints
Other restrictions
Other constraints

Data may be freely used providing that the source is mentioned. https://doi.org/10.17183/roec_turbi

Classification
Unclassified
Spatial representation type
Text, table
Metadata language
French
Character set
UTF8
Topic category
  • Oceans
N
S
E
W


Reference system identifier

EPSG

/

WGS 84 (EPSG:4326)

/

7.9

Distribution format
  • CSV

    (

    -

    )

  Point of contact

Shom Shom  

OnLine resource
Shom geoportal  
OnLine resource
ROEC_TURBI_3857_WMSV  

Mooring points ROEC Turbidity WMS

Hierarchy level
Series

Conformance result

Date ( Publication )
2010-12-08
Explanation

Information sur la conformité au règlement d'interopérabilité des séries et des services de données géographiques.

Statement

The sensors used to monitor turbidity near the bottom are: NTUS Optical Turbidimeter (Wetlabs) and Aquadopp 200m Spot Current Meter (Nortek).

The optical turbidimeter gives a qualitative information of underwater visibility. It measures the absorbance and / or the diffusion of a light ray of known wavelength by a liquid. The incident light thus reflected towards the instrument is a function of the quantity of particles suspended in the water. Optical turbidimeters give values ​​in NTU (Nephelometric Turbidity Unit) to assess the ability of water to let light (turbidity). The turbidimeters were chosen to measure at 650 nm, ie in the red. This criterion is important to consider because it means that it will be much more sensitive to mineral particles than to phytoplankton.

The punctual current meter (Aquadopp) gives information on the intensity and direction of currents near the bottom. It can also measure temperature and pressure. This sensor, in addition to serving as a turbidimeter feed, can provide elements on hydrodynamic conditions and affirm or deny the impact of currents on turbidity variations.

After calibration in the laboratory, these two sensors are then fixed on structures which can be of two types according to the depth of immersion:

- for shallow waters (St Brieuc, Morlaix, Freight, Douarnenez and Concarneau), tripod cages made of aluminum (light) welcoming the sensors, a Sonardyne LRT width, weighing and anchoring systems as well as floats;

- for large funds (Grande Vasière and Gino points), Antirion type cages fixed on a concrete ballast and which require a carrier for their deployment.

The sensors (turbidimeter and current meter) are positioned to measure less than 1 m from the bottom for turbidimeters and 2 m for current meters.

Deployed instruments acquire a measurement every 20 minutes continuously. This frequency of acquisition requires a rotation of the systems every three months to guarantee the autonomy of the batteries and thus the continuity of the measurements.

Description

gmd:MD_Metadata

File identifier
ROEC_TURBI   XML
Metadata language
French
Character set
UTF8
Hierarchy level
Series
Hierarchy level name

Jeu de données

Date stamp
2022-07-22T12:00:49
Metadata standard name

ISO 19115:2003/19139

Metadata standard version

1.0

  Point of contact

Shom Shom  

13 rue du Chatellier - CS 92803

BREST

29228

France


 
 

  Overviews

thumbnail
large_thumbnail

  Provided by

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
ROEC_TURBI   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  •